  • Huvitz Biometry Module HOCT-Biometry Module

Huvitz HOCT-Biometry Module Biometry Module

HOCT provides all the data you need for fast and straightforward calculations to optimize IOL power. Biometry from the Cornea to the Macula.
From the Cornea to the Macula, HOCT displays 2D images and provides all data along both the anterior and posterior segments.
Once the measurement is complete, the user can identify and make the necessary adjustments. Furthermore, it is possible to evaluate a dense cataract or macular defects.

Talk to a specialist

Complete Biometry

Measures from the cornea to the macula in a single examination.

Optimized IOL Calculation

Provides all the data needed to accurately calculate lens power.

Detailed 2D Images

Visualize anterior and posterior segments with clear 2D images.

Pathology Evaluation

Detects dense cataracts and macular defects for precise adjustments.

Visible Measurement via 2D Image

The user can easily adjust the lines to analyze structures by moving the cursor on the monitor in real time. This allows for personalized treatment for the atypical patient.

More Precise Biometry Exact Measurement through 2D Imaging:
Visualize and Measure on a Full 16 mm Anterior Image
* Confirmation Screen with Selection and Readjustment Option

Users can make adjustments along the axial axis, as well as remove measurements that fall outside normal values, in order to generate precise statistics for IOL calculation.

* Anterior Image

Complete for a Broader Evaluation With Wide Lens measurement, users can obtain a complete anterior image. With a single click, it is possible to identify the CCT, ACD, ACA, W-to-W, LV, TISA and TID*, contributing to the diagnosis and management of Glaucoma.

* Contact Lens Fitting with Instant Verification

The HOCT-1 allows users to verify the suitability of Rigid and Soft Contact Lenses for their patients. It also allows checking the fit of an existing Contact Lens, quickly and accurately.

* Reliable IOL Lens Power Recommendation

HOCT recommends the optimal IOL lens power, based on biometry and corneal curvature with clinical data, so that users can easily plan their surgical intervention taking into consideration dense cataracts, corneal diseases, or glaucoma.

* Display function to verify the disease basis
Imagen anterior completa, 12 types of corneal tomography, biometry data (AL, LT, CCT, ACD) and corneal tomographic image. Asymmetry comparison between right and left eye through both-eye visualization (OU display).