Clinical Areas:

Retina and Fundus

Glaucoma and Intraocular Pressure

Myopia Control

Cataract

  • Home
  • Huvitz Biometer HBM-1

Huvitz Biometer HBM-1

The Huvitz HBM-1 Optical Biometer is a state-of-the-art device designed for precise biometric measurements of ocular structures. This advanced tool continuously integrates optical biometry and corneal topography, offering a comprehensive solution for vision care professionals. With the incorporation of essential corneal topography functions for capturing keratorefractive parameters, the HBM-1 is a versatile device.

Running on the Windows 10 operating system, the HBM-1 software supports widely recognized formulas such as Holladay 1, Haigis, Hoffer Q, SRK/T, SRK II, Camellin-Calossi, and Shammas No History. These formulas enable precise calculations for various applications, including IOL (Intraocular Lens) calculation, toric IOL calculation, post-LASIK (Laser Photorefractive Keratectomy) calculation, and cataract surgery. The Huvitz HBM-1 Optical Biometer is an indispensable tool for vision care professionals seeking precision and efficiency in their practice.

Talk to a specialist

SUPERIOR OPTICAL BIOMETER

The HBM-1 is the perfect combination for cataract surgery. It allows the user to calculate IOL power in patients undergoing cataract surgery through full integration between Biometry and Topography.

The device offers a wide variety of formulas, including DCM (Dense Cataract Mode), as well as advanced Placido disc analysis technologies, ensuring more reliable results.

In addition, it performs measurements of 10 clinical parameters with greater speed and precision.

Ideal Workflow for Cataract Surgery

Achieve the most efficient workflow for cataract surgery by simultaneously measuring 10 optical biometry values and complete corneal topography. The precise calculation of intraocular lens (IOL) power is optimized through the use of multiple formulas, improving cataract surgery planning.

RELIABLE MEASUREMENT DATA AND VALUES

El HBM-1 consistently provides biometric and topographic values, ensuring reliable data even in cases of lens opacity in cataract patients. Equipped with Dense Cataract Mode (DCM), the device amplifies and re-evaluates weak light signals to ensure reliable data in patients with denser cataracts.

WIDE RANGE OF PRACTICAL APPLICATION AREAS

Track changes in patient visual acuity data, including changes in axial length (AL) and refraction. Simplifies the comparison of diagnoses derived from glasses and lenses, before and after prescription, and supports routine eye care management, such as monitoring the impact of floaters on vision.

OPTIMIZED WORKFLOW FOR CATARACT SURGERY

ALL 10 EXAMS AT THE SAME TIME

10 data types for IOL power calculation
All accurate results are based on real measurement data:
AL at #6, ANT at #8 – standard deviation (SD)
The high measurement speed minimizes patient discomfort.

Data measurement with 10 methods: Axial Length(AL), Anterior Chamber Depth(ACD), Central Corneal Thickness(CCT), Lens Thickness(LT), Keratometry, Topography, Keratoconus, Zernike Coefficients, Pupillometry, White to white

IOL POWER VALUE WITH VARIOUS FORMULAS

The measured values automatically suggest the ideal IOL power after calculation using different formulas and intraocular lens models.

Installed formulas: Barrett(Universal II, Universal II Toric, True-K, True-K Toric, Rx), Holladay, SRK2, SRK/T, HofferQ, Haigis, Camellin Calossi, Shammas No History

PREMIUM LENS PRESCRIPTION

This approach involves the prescription of premium lenses that simultaneously correct multiple visual problems such as astigmatism, myopia, presbyopia, and cataracts. It offers options such as toric IOLs for astigmatism correction, multifocal IOLs for presbyopia, and spherical IOLs for enhanced clarity, providing comprehensive solutions for patients. Furthermore, the system guides the user in selecting the most appropriate IOL to correct their specific refractive errors, resulting in better visual outcomes and greater satisfaction.

HIGHLY RELIABLE BIOMETRIC MEASUREMENT IN CATARACT PATIENTS

Accurate measurement of biometric values in cataract patients is essential for safe and reliable evaluations. This is made possible by Verified Light Interference technology, which ensures highly precise data acquisition.

This technology maintains consistent results regardless of the operator’s experience level, ensuring reliable biometric measurements for all cataract patients.

Data measurement: Axial Length(AL), Central Corneal Thickness(CCT), Anterior Chamber Depth(ACD), Lens Thickness(LT)

DCM (Dense Cataract Mode) for Dense Cataract Measurement

The Dense Cataract Mode (DCM) functionality was developed specifically for patients with dense cataracts. It uses advanced algorithm-based technology to measure axial length (AL) with remarkable precision, even in cases that present significant challenges. This ensures accurate data collection and reliable results for patients with complex cataracts.

Accurate Corneal Information and K Values

The HBM-1 provides accurate corneal information and K values (keratometry). The system offers detailed analysis and measurement data including axial and tangential mapping, refractive power and corneal elevation mapping, ensuring a comprehensive and precise evaluation of corneal characteristics, essential for various ophthalmological procedures.

Data measurement: Keratometry, Topography, Keratoconus, Zernike Coefficients, Pupillometry, White to white
Comprehensive Management “Monitoring, Regular Care” with the HBM-1

Myopia management functions for integrated management

The HBM-1 is equipped to perform meticulous tracking of the complete history of the patient’s ocular measurement data, enabling the generation of graphical representations showing changes in axial length (AL) and refractive values over time. In addition, it features the capability to integrate RX (REF) data from Huvitz RK series instruments, serving as a valuable foundation for precise diagnostic evaluations. Furthermore, the HBM-1 provides support to patients during prescription and surgery procedures for Ortho-K lenses, allowing a comprehensive comparison of variations in ocular measurements before and after lens use. This function also facilitates the observation and discussion of anisometropia with the patient, enhancing the patient experience and understanding of ocular health.

CONTACT LENS FIT VERIFICATION

Capture a fluorescein image without direct injection using liquid fluorescence.

Early keratoconus detection prediction.

Calculates KPI (Keratoconus Prediction Index) values to predict keratoconus.

ZERNIKE ANALYSIS FOR DIVERSE VARIABLES

Through the analysis of Zernike coefficients/map, various variables are systematically obtained, such as variations in ocular refractive power and irregular astigmatism.

USER-CENTERED ENVIRONMENT

Simplified Connection with Various Devices through Connectivity

The standard format facilitates the connection of each device to the DICOM system, enabling seamless integration with health information systems. Measured data can be displayed and analyzed on a computer (PC) using Huvitz HIIS-1 software, ensuring efficient information management and easy access for healthcare professionals.

Image and Sound Guidance Indicating the Start and End of the Examination

An audible alert system was implemented to inform the patient when to “open their eyes” or “close their eyes.” This feature was developed to minimize patient effort and discomfort, providing a more comfortable and relaxed experience during the examination.

∙ One beep (once) to start the measurement: instructs the patient to open their eyes
∙ One beep (twice) to end the measurement: instructs the patient to close their eyes

Reports for Evaluation and Diagnosis

El HBM-1 provides systematized reports based on IOL power values obtained through Biometry, Topography, and IOL calculations.

Micro-Movement Detection with High-Precision Auto Tracking

Through the Auto Focus mechanism, the HBM-1 can track the measurement point quickly, easily, and accurately, performing measurements without the need for manual focusing.

The Auto Tracking guide assists in the correct positioning of the joystick and chin rest, reducing errors during the examination.

Integrated PC: Space and Cost Savings

The system conveniently displays a wide variety of information, including measurements and analysis reports, directly on the integrated 10.1″ LCD touchscreen, eliminating the need for an external PC.



Specifications

Manuals & Catalogs

Catalogs

Huvitz Biometer HBM-1

Manuals

Huvitz Biometer HBM-1